Supply House Times logo Supply House Times
search
cart
facebook instagram twitter linkedin youtube
  • Sign In
  • Create Account
  • Sign Out
  • My Account
Supply House Times logo Supply House Times
  • NEWS
    • ASA NEWS
    • Company News
  • PRODUCTS
    • Interactive Spotlights
  • COLUMNS
    • Natalie Forster: From the Editor
    • Alicia Branham: Marketing Matters
    • Brad Williams: Succession Planning
    • Melissa Rasico: Luxury Plumbing Lounge
    • Letter from ASA President
    • Guest Columnists
    • Safety Columnists
  • MARKETS
    • Codes & Legislation
    • Heating & Cooling
    • Industrial PVF
    • Plumbing
    • Radiant & Hydronics
    • Solar Thermal | Geothermal
    • Technology
    • Women in Industry
  • BATH & KITCHEN PRO
    • Bath & Kitchen News
    • Bath & Kitchen Products
  • SPECIAL EDITIONS
    • B.I.G. Book Directory
    • Premier 150
    • Rep Locator Directory
  • MEDIA
    • Podcasts
    • Videos
    • eBooks
    • Webinars
  • RESOURCES
    • Radiant Comfort Report
    • Industry Calendar
    • Industry Links
    • Custom Content & Marketing Services
    • Market Research
    • Supply House Times Store
  • EMAG
    • EMAGAZINE
    • ARCHIVE ISSUES
    • CONTACT
    • ADVERTISE
  • SIGN UP!
Fire Protection

Asset Protection

The evolution of foam fire suppression in high-value storage facilities.

By Christine Swanson
August 1, 2011
Many of us have seen the video of the aircraft hangar accidentally filled with white, billowy, high-expansion fire suppression foam during a hangar system test that ran too long. (Click on YouTube and type “Fire Foam Test Goes Very Wrong!” in the search box.)

Yes, I mean the one where the hangar doors were opened afterward and the foam seemed to flow out onto the aircraft operations area, almost engulfing a small jet sitting outside the hangar.

If you have not worked with an aircraft hangar or similar high-value storage facility, you may not have heard about the continuing evolution in foam fire suppression methods. Desired suppression systems in aircraft hangars are shifting from low-expansion (dense) foam discharged overhead to high-expansion foam discharged overhead or low-expansion foam discharged at the floor level.

Any of these systems are still being combined with ceiling water sprinklers in either open sprinkler (deluge) configuration, or in a wet pipe, closed/fused sprinkler configuration. Because the sprinkler droplets will have a deleterious effect on the foam blanket, extra foam discharge is calculated into the design to compensate. Water from sprinklers also will have a cooling effect because the foam smothers a fire. The result is the fire is usually extinguished, but there is foam residue and water left on the floor, on any equipment in the area and in the floor spill containment system.

Agents/Systems

High-expansion foam systems are considered by many to be the most effective systems with the lowest impact on a facility and its contents. High-expansion foam flows to smother low-level fires. Low-expansion, aqueous film-forming foam is still in strong use, but its application has changed from being discharged high above the hangar floor from foam generators to being sprayed from grate nozzles at floor level. FM-approved in 2003, the Viking Grate Nozzle System continues to provide an effective application of AFFF at the floor level instead of being discharged from high-level foam generators. NFPA 409 — Standard on Aircraft Hangars — gives guidance on application combinations that include those described herein.

Hangars

Without restating all hangar classifications mentioned in NFPA 409, Class I hangars require the highest level of suppression protection of Classes I, II and III. Class I hangars may be protected by:


1. A foam-water deluge system with supplementary suppression system; or

2. A combination automatic sprinkler system and low-level, low-expansion or low-level high-expansion foam system.
The obstacles to fire suppression in hangars include suppressing fuel fires under wing shadows and still protecting the high-value aircraft and its sensitive electronics. Given that AFFF is a low-expansion foam and tends to flow in a blanket over a fuel spill, smothering fires and re-flash, it is effective when discharged at floor level under fixed-wing as well as rotary-wing aircraft. High-expansion foam is effective due to it being a less-dense foam that floats to suppress fires above and below wing shadows.

Solution Containment

As we strive to protect the environment from spills, containment of runoff from suppression agent discharge is a serious concern. Usually, one would think this means suppression agent spills and discharge. However, potable water also is a threat to the environment because it upsets the ecological balance of the area and groundwater surrounding a facility.

Therefore, we size containment to accommodate water and agent discharge unless site-specific codes allow otherwise. That can mean a containment tank size starting at 30,000 gallons for a moderately sized hangar with an AFFF floor grate nozzle system and overhead wet pipe sprinklers. Naval facilities standards for hangars include UFC 4-211-01N, which does not require containment tanks to be sized for hose or sprinkler runoff, only suppression agent solution due to accidental foam system discharge.

Foam systems are only required to have enough suppression agent for 10 minutes of discharge and, therefore, require limited containment volume. Sizing containment tanks to accommodate foam solution, as well as sprinkler runoff and hose stream runoff would mean an almost unlimited tank size because sprinklers and hoses are not limited to a finite run time due to their dependency on manual shutoff in most instances.

System Options

A low-flow water option not yet accepted as a primary suppression system in replacement of wet pipe sprinklers is on the horizon. Victaulic’s Vortex system is a fine water mist and nitrogen mixture used for total flooding, but is not currently appropriate for a four-story hangar because the application is limited by hangar volume as well as hangar height. Surprisingly, the mist cloud moves fast enough to overcome open doors, but within limits.

Floor grate and localized misting technology is continuing to evolve and appears to present the lowest impact on containment size and environmental impact. Maintenance of misting systems and water quality still remain a factor in long-term misting system costs and reliability. The current applications of overhead wet pipe sprinklers, combined with foam suppression systems, are proven to be the most reliable. 

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

Christine Swanson, PE, FPE, CFPS, is a registered Professional Engineer in Fire Protection Engineering. She has been working in the industry of life safety and consumer product safety since 1990, with firms including Caterpillar, Underwriters Laboratories, Lockheed Martin, Federal Aviation Administration, Gage Babcock and Associates, Fire Safety Solutions, Clark Nexsen, and currently Hankins and Anderson Architects and Engineers. She can be reached at c.swanson@ha-inc.com or 757-213-6059.

Recommended Content

JOIN TODAY
to unlock your recommendations.

Already have an account? Sign In

  • Stock financial index show successful investment on property business and construction industry with graph and chart for presentation and report background.

    2025 predictions: Twelve trends supply houses should know

    As 2024 ends, I’ll review last year’s predictions and...
    Plumbing
    By: Brad Williams
  • Background of aerial view of Industrial container port part of shipping in nighttime with a blue overlay.

    2025 Next Gen ALL-STARS: Top 20 Under 40 PHCP-PVF Professionals

    The future of the PHCP-PVF industry is being shaped by a...
    Heating & Cooling
    By: Natalie Forster
  • Premier 150: The top PHCP-PVF Distributors of 2026

    Premier 150: The Top PHCP-PVF Distributors of 2026

    Combined revenue across this year’s Premier 150 once...
    Industrial PVF
    By: Natalie Forster
Manage My Account
  • eMagazine
  • Newsletters
  • Manage My Preferences
  • Online Registration
  • Subscription Customer Service

More Videos

Popular Stories

Premier 150: The top PHCP-PVF Distributors of 2026

Premier 150: The Top PHCP-PVF Distributors of 2026

Jeff Dice

Built to Scale, Designed to Stay Local: Lessons From Winsupply at 70

Erin McCusker, Chief Impact Officer, LIXIL

LIXIL Elevates Impact Strategy to the Next Phase, Appoints Chief Impact Officer

2026 Premier Rankings

Events

December 30, 2030

Webinar Sponsorship Information

For webinar sponsorship information, visit www.bnpevents.com/webinars or email webinars@bnpmedia.com.

View All Submit An Event

Poll

Identifying Daily Time Loss Areas for Your Team

Where does your team lose the most time each day?
View Results Poll Archive

Products

The Water Came To A Stop

The Water Came To A Stop

See More Products

Download the FREE 2025 Water Conservation, Quality & Safety eBook

Download the Fifth annual Bath & Kitchen Pro eBook

Related Articles

  • Maximizing changes

    See More
  • Why didn’t my fire sprinkler system work?

    See More
×

Stay in the know on the latest PHCP-PVF industry trends.

Get tailored content delivered your way.

JOIN TODAY!
  • RESOURCES
    • Advertise
    • Contact Us
    • Directories
    • Store
    • Want More
    • Plumbing & Mechanical
  • SIGN UP TODAY
    • Create Account
    • eMagazine
    • Newsletter
    • Customer Service
    • Manage Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing