Supply House Times logo Supply House Times
search
cart
facebook instagram twitter linkedin youtube
  • Sign In
  • Create Account
  • Sign Out
  • My Account
Supply House Times logo Supply House Times
  • NEWS
    • ASA NEWS
    • Company News
  • PRODUCTS
    • Interactive Spotlights
  • COLUMNS
    • Natalie Forster: From the Editor
    • Alicia Branham: Marketing Matters
    • Brad Williams: Succession Planning
    • Melissa Rasico: Luxury Plumbing Lounge
    • Letter from ASA President
    • Guest Columnists
    • Safety Columnists
  • MARKETS
    • Codes & Legislation
    • Heating & Cooling
    • Industrial PVF
    • Plumbing
    • Radiant & Hydronics
    • Solar Thermal | Geothermal
    • Technology
    • Women in Industry
  • BATH & KITCHEN PRO
    • Bath & Kitchen News
    • Bath & Kitchen Products
  • SPECIAL EDITIONS
    • B.I.G. Book Directory
    • Premier 150
    • Rep Locator Directory
  • MEDIA
    • Podcasts
    • Videos
    • eBooks
    • Webinars
  • RESOURCES
    • Radiant Comfort Report
    • Industry Calendar
    • Industry Links
    • Custom Content & Marketing Services
    • Market Research
    • Supply House Times Store
  • EMAG
    • EMAGAZINE
    • ARCHIVE ISSUES
    • CONTACT
    • ADVERTISE
  • SIGN UP!
ColumnistsHeating & CoolingRadiant & HydronicsDan Holohan: Heating Help

10 things you should know about steam traps

Don’t get stuck!

By Dan Holohan
August 13, 2014

Let’s get right to it with some steam-trap advice.

If the F&T trap is the same size as the pipe, it’s the wrong size. I was checking the size of trap that was at the bottom of a 6-in. main that went up 35 stories in a building. The proper size for that trap would have been 1 1/4 in. Of course, the trap that was in place was much larger and that’s the reason why it had failed. An oversized F&T trap barely opens to dump the little bit of condensate it has to handle. The trap’s pin rides too closely to the trap’s seat and that leads to metal erosion of both the pin and the seat as the condensate screams by the barely open exit hole. I asked the engineer why the trap was so large. He said that 1 1/4 in. would have looked stupid. Really.

In every case, when you see an F&T trap in a heating system and it’s the size of the pipe it serves, know that it is oversized. Someone paid too much and that oversized trap will fail.

Metal chimney of a geothermal power station with stainless steel pipe structure with smoke and steam.
Image courtesy of Denis Torkhov / iStock / Getty Images Plus

But it will look good.

All traps need Delta-P. Without a difference in pressure, a steam trap will just sit there like a metal meatloaf. You need Delta-P to go get the condensate to move through the trap. That’s why you’ll usually see traps mounted several feet below steam-to-water heat exchangers. When the exchanger’s control valve shuts, there’s no steam pressure to move the condensate out of the heat exchange. A vacuum breaker on the shell will open (and please make sure one is there) to let air into the shell. Then the static weight of the water between the outlet of the heat exchanger and the inlet of the steam trap will provide the pressure needed to move the condensate through the trap. It’s all about Delta-P.

Beware of backpressure. Keep your eyes on the outlet side of that trap as well. Does the condensate have to go uphill from there? If so, there will be a check valve and backpressure. You’ll need to consider this when sizing the trap. Also, look at what else is connected to the outlet side of the trap. Are there other steam traps? At what pressure are they discharging? Are they working properly? Are they putting flash steam into the return line? That also will create backpressure. Open your eyes and look around.

If you double-trap a return line, the condensate will barely move. Here again, think about Delta-P. Steam traps trap steam. If you double-trap a return line, there will be no pressure after the first trap to push condensate through the second trap. Remember, where there is no difference in pressure there can be no flow. So the condensate lies in the pipe and blocks the air that’s trying to vent. There’s no heat because if the air can’t get out, the steam can’t get in. Oh, and the boiler will probably go off on low-water because the condensate isn’t returning.

The automatic feeder will open to replace the water that’s not returning, and when the steaming cycle is over and the condensate finally does return, the boiler will flood. Or the feed pump’s receiver will overflow. And it’s all because of the double traps.

Traps don’t vent air. Air moves through a trap and into the return line, but from there it has to have a way to get out of the system or the steam won’t go where you need it to go. If the discharge of the trap goes upward, that’s going to form a water seal. Air won’t vent through a water seal (think about a sink trap). And again, where there is air, steam will not go.

Think like air when you’re troubleshooting. Ask yourself, “If I were air, could I get out?” Follow the path of the air and look for the vents. If you don’t see them, that’s why the building isn’t heating well.

Don’t use bucket traps near a pressure-reducing valve. To get a bucket trap to work you first have to prime it with water. When a pressure-reducing valve lowers the pressure of the steam, you wind up with superheat. That’s steam that’s hotter than it ought to be for the pressure that it’s at. Those extra Btu need to go somewhere, and they will gladly go into that bucket trap’s prime water and cause it to turn to steam and leave the trap. Without the prime, the trap will blow steam into the return lines. Not good, and this is why you’ll usually see thermodisc-type traps near PRV stations.

Don’t trap lines that go to gravity wet returns. A gravity-return system is one that doesn’t have a condensate pump or a boiler-feed pump. If you have, say, a steam unit heater, its return line will need a big main vent to get the air out of the unit heater. That vent should be on the outlet side of the unit heater. But if the condensate is draining into a wet return, just let it fall by gravity into that line. There’s no need for a trap here because all the pipes below the boiler’s waterline are permanently under water. If you use a trap, it will cause condensate to back up into the unit heater. Also not good.

Some traps let condensate flash back to steam. Particularly F&T traps because they don’t sense the temperature of the condensate. They dump condensate at saturated-steam temperature. That means some of the condensate will flash back into steam when it enters the return line. That causes backpressure, which can affect the operation of other traps. If the trap is near a vented boiler-feed pump’s receiver, that flash steam will show up as puffs of steam coming out of the vent. That’s liable to cause some knucklehead to put a cap on the vent line. Lower the steam pressure to get rid of the flash steam. Most steam-heating systems are running at pressures that are too high anyway, so try lowering it.

Radiator traps last about 10 years. In a typical year, a radiator trap will cycle about 175,000 times. That’s why, after about 10 years, they’re ready to retire. If the trap fails closed, there will be no heat and someone will notice. But if the trap fails open, that radiator will continue to heat and that person won’t complain. The steam, however, will now be in the return lines, causing backpressure on the other traps.

Those people will complain because if the air can’t get out of their radiators, the steam can’t get in. And air won’t go into a return line that has steam pressure in it. Ten years is what you get from a trap. If no one has ever looked at them, that’s probably where you’ll find the solution to the heating problem.

Master traps make no sense. When traps go bad, some installers think they can solve all the problems by piping one enormous trap right at the inlet to the boiler-feed pump. They liken this spot to the trunk of a tree. They don’t understand why all those traps are out there on the tree branches. They don’t realize that radiator traps set up the points of pressure and no-pressure throughout the system.

In this way, they’re similar to balancing valves in a hot-water system. These installers think the Dead Men who first piped all those traps were stupid. Why would they have used so many traps when they could have gotten by with just one humungous trap down there in the basement? It seems so simple to them. 

These installers are world-class idiots.


HELPFUL LINKS:

  • HeatingHelp.com
  • Contact Us
  • Follow Supply House Times on Twitter!
  • Find Supply House Times on Facebook!
  • Join Supply House Times on LinkedIn!
  •  Supply House Times is on Google+ 
KEYWORDS: heating hydronics steam

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

Dan is the hydronics contributing editor for Supply House Times. He founded the popular www.HeatingHelp.com web site where you'll find just that - Heating Help. Post your technical challenges on The Wall bulletin board and get input from some of the best in the business. You can reach him at dan@heatinghelp.com. He loves hearing from you!

Recommended Content

JOIN TODAY
to unlock your recommendations.

Already have an account? Sign In

  • Stock financial index show successful investment on property business and construction industry with graph and chart for presentation and report background.

    2025 predictions: Twelve trends supply houses should know

    As 2024 ends, I’ll review last year’s predictions and...
    Plumbing
    By: Brad Williams
  • Background of aerial view of Industrial container port part of shipping in nighttime with a blue overlay.

    2025 Next Gen ALL-STARS: Top 20 Under 40 PHCP-PVF Professionals

    The future of the PHCP-PVF industry is being shaped by a...
    Heating & Cooling
    By: Natalie Forster
  • Premier 150: The top PHCP-PVF Distributors of 2026

    Premier 150: The Top PHCP-PVF Distributors of 2026

    Combined revenue across this year’s Premier 150 once...
    Market Sectors
    By: Natalie Forster
Manage My Account
  • eMagazine
  • Newsletters
  • Manage My Preferences
  • Online Registration
  • Subscription Customer Service

More Videos

Popular Stories

Premier 150: The top PHCP-PVF Distributors of 2026

Premier 150: The Top PHCP-PVF Distributors of 2026

Jeff Dice

Built to Scale, Designed to Stay Local: Lessons From Winsupply at 70

Erin McCusker, Chief Impact Officer, LIXIL

LIXIL Elevates Impact Strategy to the Next Phase, Appoints Chief Impact Officer

2026 Premier Rankings

Events

December 30, 2030

Webinar Sponsorship Information

For webinar sponsorship information, visit www.bnpevents.com/webinars or email webinars@bnpmedia.com.

View All Submit An Event

Poll

Identifying Daily Time Loss Areas for Your Team

Where does your team lose the most time each day?
View Results Poll Archive

Products

The Water Came To A Stop

The Water Came To A Stop

See More Products

Download the FREE 2025 Water Conservation, Quality & Safety eBook

Download the Fifth annual Bath & Kitchen Pro eBook

Related Articles

  • Dan Holohan: The rules for steam traps

    See More
  • Dan Holohan: Does it pay to fix those steam traps

    See More
  • Dan Holohan: All you want to know about plastics

    See More

Related Products

See More Products
  • lessons-learned1.gif

    Lessons Learned: Connecting New Boilers to Old Pipes

  • Classic Hydronics - How To Get The Most From Those Older Hot-Water Heating Systems

  • lost art steam heating.jpg

    The Lost Art of Steam Heating Revisited

See More Products

Related Directories

  • Maid O' Mist LLC

    Since 1932, Maid O’Mist has been manufacturing the industry's most complete line of air elimination valves. We offer fifteen models of air elimination valves, twenty models of steam valves, and seven models of vertical/horizontal float-operated water level controls to meet your hydronic, steam, solar, and water application needs. Maid O’ Mist has a worldwide distribution with stocking representatives in the United States and Canada. All models are in stock and ready for same-day/next-day shipment. We can cross-reference most competitor part numbers to guide you to a Maid O’ Mist product. All application and technical information is readily available to help you decide on what product best suits your needs.
  • Access Marketing Group

    Access Marketing represents the union of experienced personnel from the plumbing, heating, and specification channels. Our objective is to provide our manufacturers with goal attainment by delivering diversification, market leadership, and industry know-how.
  • PlatskyHVAC

    The PlatskyHVAC group has been a Manufacturing Representative in the Heating and Cooling industry for 90 years. We currently serve metro New York / New Jersey and the surrounding areas. Our belief in field support, technical knowledge, and doing the right thing on behalf of our customers and manufacturers sets us apart.
×

Stay in the know on the latest PHCP-PVF industry trends.

Get tailored content delivered your way.

JOIN TODAY!
  • RESOURCES
    • Advertise
    • Contact Us
    • Directories
    • Store
    • Want More
    • Plumbing & Mechanical
  • SIGN UP TODAY
    • Create Account
    • eMagazine
    • Newsletter
    • Customer Service
    • Manage Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing