Supply House Times logo Supply House Times
search
cart
facebook instagram twitter linkedin youtube
  • Sign In
  • Create Account
  • Sign Out
  • My Account
Supply House Times logo Supply House Times
  • NEWS
    • ASA NEWS
    • Company News
  • PRODUCTS
    • Interactive Spotlights
  • COLUMNS
    • Natalie Forster: From the Editor
    • Alicia Branham: Marketing Matters
    • Brad Williams: Succession Planning
    • Melissa Rasico: Luxury Plumbing Lounge
    • Letter from ASA President
    • Guest Columnists
    • Safety Columnists
  • MARKETS
    • Codes & Legislation
    • Heating & Cooling
    • Industrial PVF
    • Plumbing
    • Radiant & Hydronics
    • Solar Thermal | Geothermal
    • Technology
    • Women in Industry
  • BATH & KITCHEN PRO
    • Bath & Kitchen News
    • Bath & Kitchen Products
  • SPECIAL EDITIONS
    • B.I.G. Book Directory
    • Premier 150
    • Rep Locator Directory
  • MEDIA
    • Podcasts
    • Videos
    • eBooks
    • Webinars
  • RESOURCES
    • Radiant Comfort Report
    • Industry Calendar
    • Industry Links
    • Custom Content & Marketing Services
    • Market Research
    • Supply House Times Store
  • EMAG
    • EMAGAZINE
    • ARCHIVE ISSUES
    • CONTACT
    • ADVERTISE
  • SIGN UP!
ColumnistsRadiant & HydronicsDan Holohan: Heating Help

The nature of diverter tees

Flow in a closed system is always about traffic.

February 1, 2012
Photo courtesy of Taco


When I think hydronics, I think traffic. I can’t help it. The two are so similar.

Here, imagine you’re the water in a main heating pipe. You’re driving down the pipe when you notice an accident up ahead. There’s a lane or two closed up there, so you hop on the service road. But you’ll only do that if you’re a local and you know that the service road doesn’t involve a 100-mile detour. If you knew that, you’d probably stay on the highway, wouldn’t you?

Sure you would, and so would I.

This is why there sometimes is no heat in that radiator up on the second floor - the one that the diverter tee and its partner, the standard tee down in the basement, are supposed to take care of. Sure, it looks like an air problem, but it’s a flow-balance problem. You prove this by bleeding the radiator. You don’t get any air, which means it ain’t an air problem.

Time to stop bleeding.

Flow in a closed system is always about traffic. These diverter tees, which are on so many older systems, don’t “scoop” water. They just direct the traffic. If it’s too congested on this main road, the water will get off and take that other road, but only if the detour isn’t that long. The difference in pressure between the different ports of the tees decides where the traffic goes.

Can you see it in your mind’s eye? Can you feel it?

Good.

Most diverter tees come with a ring that’s cast into one side of the tee’s run. When you see these tees on a job, the rings should always be between the two pipes that run out to the radiator that the tees serve. Sometimes we use just one tee, but often it takes two tees to get the job done.

Preventing a traffic jam

Here are the rules of thumb:

1. If the radiator is on the floor directly above the main, one tee should do the trick. That tee should be on the return pipe (coming from the radiator), with the ring on the inboard side of the pipes that feed the radiator.

2. If the radiator is on the second floor, you’ll need two tees, and the pipe leading to the radiator should be one size larger than what you would normally use. For instance, 1/2” for the first floor becomes 3/4” if the radiator is on the second floor. This is to keep the pressure drop to and from the radiator to a minimum. Think like water.

3. The tees should ideally be the width of the radiator apart. When these tees were popular, so were freestanding, cast-iron radiators and convectors. These radiators and convectors were typically about three feet wide, and that’s why you’ll often see the tees placed at that distance apart on the main.

4. If you remove a freestanding radiator or convector and replace it with lots of linear feet of baseboard radiation, don’t be surprised if the water decides to stay in the main. You just increased the resistance to flow by increasing the length of the detour. You made the side road longer.

5. If the radiators are below the main, use a diverter tee on both the supply and the return, be certain that the rings on the tees are between the pipes that go to the radiator (meaning that the tees will face in opposite directions), and make sure the tees are as wide apart as the radiator is long.

6. If you remove a radiator and you’re not going to replace it, connect the bulls of the two tees with a 1/2” pipe so that water has a place to go. Otherwise, you’re leaving two major accidents on the main road, and closing the service road at the same time. That’s going to slow the flow of traffic to the whole system.

7. One more thing: Staggering the tees (supply/return/supply/return) will increase the resistance to flow along the main and encourage more water to flow to the radiators. That’s an old-timer’s trick.

Thermostatic radiator valves

While I have you thinking about the difference in pressure and how it can make or break a job with diverter tees, let’s consider thermostatic radiator valves.

These nonelectric zone valves seem like naturals for zoning a one-pipe, diverter-tee system, and I like them a lot for that, but you have to be very careful when you choose them. These valves, even when they’re wide open, offer a resistance to the flow of water through the radiator, and that resistance might be enough to stop the water altogether.

The TRV has two parts. The part that attaches to the pipe is a normally open, spring-loaded valve. You’ll attach to this the other part of the TRV, which is an operator that contains either a fluid or a wax that is very sensitive to changes in room-air temperature. As the temperature rises or falls, the fluid or the wax inside the operator will expand and contract, moving the spring-loaded valve open or closed. Control the flow and you’ll control the heat. You can adjust a TRV to whatever temperature you’d like in the room it serves, typically between 50° and 90° F.

What you need to watch out for, though, is the TRV’s pressure drop. You can see this in the valve manufacturer’s literature. They show it as Cv. That’s an engineering term that always appears as a number.

You’ll see something like this: Cv = 2.5. That 2.5 is gallons per minute. Any number that appears after the = in the Cv equation will always be gpm, and what the equation is saying is that when, in this case, 2.5 gpm flows across that particular valve, there will be a corresponding drop in pressure from one side of the valve to the other of 1 psi.

Cv always relates to a difference in pressure of 1 psi. If you look at two valves, one where the Cv = 2.5, and the other where the Cv = 3.0, the latter valve will have less of a pressure drop.

Think it through. With the first valve, you get a 1-psi drop in pressure with just 2.5 gpm flowing. The second valve can flow a full 3 gpm before the water suffers that same 1-psi pressure drop.

So, if I were choosing between those two TRVs for my diverter-tee system, I’d probably choose the second valve because it has a higher Cv number, which means it offers less resistance to flow. I don’t want the valve, when fully open and just sitting there, to present my flow with so much resistance that flow just stops because, where there is no flow, there is no heat.

That would be one major traffic jam.

Links

  • Contact Supply House Times
  • Follow Supply House Times on Twitter!
KEYWORDS: hydronics

Share This Story

Looking for a reprint of this article?
From high-res PDFs to custom plaques, order your copy today!

Recommended Content

JOIN TODAY
to unlock your recommendations.

Already have an account? Sign In

  • Stock financial index show successful investment on property business and construction industry with graph and chart for presentation and report background.

    2025 predictions: Twelve trends supply houses should know

    As 2024 ends, I’ll review last year’s predictions and...
    PHCP and PVF Technology & Operations
    By: Brad Williams
  • Background of aerial view of Industrial container port part of shipping in nighttime with a blue overlay.

    2025 Next Gen ALL-STARS: Top 20 Under 40 PHCP-PVF Professionals

    The future of the PHCP-PVF industry is being shaped by a...
    Market Sectors
    By: Natalie Forster
  • Premier 150: The top PHCP-PVF Distributors of 2026

    Premier 150: The Top PHCP-PVF Distributors of 2026

    Combined revenue across this year’s Premier 150 once...
    Industrial PVF
    By: Natalie Forster
Manage My Account
  • eMagazine
  • Newsletters
  • Manage My Preferences
  • Online Registration
  • Subscription Customer Service

More Videos

Popular Stories

Jeff Dice

Built to Scale, Designed to Stay Local: Lessons From Winsupply at 70

Commercial outlook tech looking at pipes

Commercial Market Outlook: Retrofit Projects Lead the Way

A graphic showing an arrow moving upward, with "PHCP-PVF Price Increases" written above it.

PHCP-PVF Price Increases May 2026

2026 Premier Rankings

Events

December 30, 2030

Webinar Sponsorship Information

For webinar sponsorship information, visit www.bnpevents.com/webinars or email webinars@bnpmedia.com.

View All Submit An Event

Poll

Identifying Daily Time Loss Areas for Your Team

Where does your team lose the most time each day?
View Results Poll Archive

Products

The Water Came To A Stop

The Water Came To A Stop

See More Products

Download the FREE 2025 Water Conservation, Quality & Safety eBook

Download the Fifth annual Bath & Kitchen Pro eBook

Related Articles

  • HVAC units on the roof

    The intertwined nature of HVAC and global warming

    See More
  • Product Preview…Diverter Valve/Backflow Preventer

    See More
  • Product Preview…PEX Monoflow Tees

    See More

Related Products

See More Products
  • lost art steam heating.jpg

    The Lost Art of Steam Heating Revisited

See More Products

Related Directories

  • Pure n Natural Systems

    Discover Pure n Natural Systems, your source for advanced air purifier and water filtration systems. With humidity control products and U.S.-based reliability, we bring healthier environments to homes, offices, and commercial spaces. Our team offers holistic solutions as a trusted provider of water purification services, air filtration services, HVAC equipment, and water treatment equipment. From heating & air conditioning support to being a home and commercial dehumidifier supplier, we deliver equipment made for performance and built to last. Businesses also rely on us as a smoke and odor control equipment supplier and filtration store backed by decades of expertise and verified results. Take control of your air and water today with systems that work. Explore Pure n Natural and experience clean living without compromise. We offer advanced air purifier systems and water filtration systems for both home and commercial applications. Enhance your indoor environment with Pure n Natural Systems!
  • Sauna360 dba Amerec

    At Amerec, we have a strong commitment to the nature that surrounds us. We continually challenge industry standards in sustainability and performance and we succeed in delivering products of the highest quality, while being mindful of what materials we use and the footprint its use leaves.
×

Stay in the know on the latest PHCP-PVF industry trends.

Get tailored content delivered your way.

JOIN TODAY!
  • RESOURCES
    • Advertise
    • Contact Us
    • Directories
    • Store
    • Want More
    • Plumbing & Mechanical
  • SIGN UP TODAY
    • Create Account
    • eMagazine
    • Newsletter
    • Customer Service
    • Manage Preferences
  • SERVICES
    • Marketing Services
    • Reprints
    • Market Research
    • List Rental
    • Survey/Respondent Access
  • STAY CONNECTED
    • LinkedIn
    • Facebook
    • Instagram
    • YouTube
    • X (Twitter)
  • PRIVACY
    • PRIVACY POLICY
    • TERMS & CONDITIONS
    • DO NOT SELL MY PERSONAL INFORMATION
    • PRIVACY REQUEST
    • ACCESSIBILITY

Copyright ©2026. All Rights Reserved BNP Media, Inc. and BNP Media II, LLC.

Design, CMS, Hosting & Web Development :: ePublishing